Reliable Transformer &
Cable Accessory Solutions

Source factory-direct components with stable quality, practical lead times, and export-ready support.

  • ISO 9001 Certified Quality
  • Factory Direct OEM/ODM Support
  • Fast Global Delivery

Request A Quote

Fill out the form below to receive our catalog and pricing.

Contact Form Demo
Cable Accessories Series

Cold Shrink Cable Accessories for Medium Voltage Cable Systems

Complete cold shrink solutions for indoor and outdoor terminations and straight-through joints, supporting 10kV and 35kV class distribution cable projects with stable insulation performance and fast field installation.

OEM/ODM Support • Fast Technical Response • Export Documentation
Voltage Class 8.7/15kV & 26/35kV
Product Scope Termination & Joint Kits
Application MV Distribution Cable Networks
Product Definition

What Are Cold Shrink Cable Accessories?

Cold shrink cable accessories are pre-expanded silicone insulation components used for medium-voltage cable terminations and joints. A typical cold shrink cable termination or cold shrink cable joint is installed by removing the support core, allowing the body to shrink and seal tightly on the cable surface without external heating. This makes medium voltage cold shrink accessories highly practical for utility, industrial, and maintenance projects requiring stable insulation and efficient on-site installation.

  • 1
    No Heat Source Needed — installation is completed without flame or torch, improving site safety and consistency.
  • 2
    Stable Insulation Interface — pre-expanded silicone structure helps maintain reliable electrical stress control.
  • 3
    Project-Ready Product Scope — supports indoor/outdoor terminations and straight-through joints for 10kV and 35kV class systems.
ZeeyiElec provides cold shrink solutions for MV cable systems, with model mapping support based on voltage class, cable structure, and conductor range.
Field Installation Cable Preparation
Core Step Position Pre-Expanded Component
This Technology Remove Core, Auto-Shrink & Seal
Final Function Insulation, Stress Control & Sealing
Product Families

Cold Shrink Cable Accessories for 10kV and 35kV Systems

Structured around outdoor terminations, indoor terminations, and straight-through joints. These product families support medium-voltage cable projects with clear model mapping and engineering-ready kit configuration.

10kV 10kV 3-Core Outdoor Termination Kit Structure Diagram

10kV 3-Core Outdoor Termination

Family: Outdoor Termination Kit

  • For medium-voltage 3-core cable termination points.
  • Designed for outdoor installation environments.
  • Cold shrink installation without heat source.

Reference: WLS series (8.7/15kV class).

10kV 10kV 3-Core Indoor Termination Kit Structure Diagram

10kV 3-Core Indoor Termination

Family: Indoor Termination Kit

  • For switchroom and indoor cable end treatment.
  • Compact structure for controlled indoor spaces.
  • Stable insulation interface with pre-expanded design.

Reference: NLS series (8.7/15kV class).

10kV 10kV 3-Core Straight Through Joint Cross-Section

10kV 3-Core Straight Through Joint

Family: Intermediate Joint Kit

  • For cable extension and route continuity.
  • Cross-section architecture supports layered insulation recovery.
  • Suitable for MV distribution project maintenance and retrofit.

Reference: JLS series (8.7/15kV class).

35kV 35kV 3-Core Outdoor Termination Engineering Drawing

35kV 3-Core Outdoor Termination

Family: Outdoor Termination Kit

  • For higher-voltage outdoor cable terminations.
  • Dimensioned engineering drawing for installation planning.
  • Built for distribution and utility connection points.

Reference: WLS series (26/35kV class).

35kV 35kV 3-Core Indoor Termination Engineering Drawing

35kV 3-Core Indoor Termination

Family: Indoor Termination Kit

  • Configured for indoor MV/HV transition sections.
  • Drawing-based dimensional control for panel/substation use.
  • Consistent kit layout supports installation repeatability.

Reference: NLS series (26/35kV class).

35kV 35kV 3-Core Straight Through Joint Cross-Section

35kV 3-Core Straight Through Joint

Family: Intermediate Joint Kit

  • For high-reliability cable joining in 35kV networks.
  • Cross-section design highlights stress control and shielding continuity.
  • Supports project-level replacement and extension works.

Reference: JLS series (26/35kV class).

Compare the product families in the specifications and model tables below. For an exact kit recommendation, provide your cable voltage rating, core count, conductor cross-section, insulation outside diameter, and installation environment.

×
Engineering Data

Cold Shrink Cable Accessories Specifications & Model Tables

Identify the voltage class, termination or joint family, core count and conductor size index. Confirm dimensional fit against the exact cable and kit documentation before ordering.

Conductor cross-section selection

Catalogue model indices are voltage-specific. Cross-sections below are in mm²; they are not insulation diameters.

Size index X8.7/15 kV26/35 kV
125–5050–95
270–120120–185
3150–240240–400
4300–400500–630
5500–630Not listed

8.7/15 kV model families

Replace X using the matching voltage column above. Example: WLS-8.7/15-3.2 corresponds to the 70–120 mm² catalogue range.

FamilyCable coresModel patternSize indices
Outdoor terminationSingle-coreWLS-8.7/15-1.XX = 1–5
Outdoor terminationThree-coreWLS-8.7/15-3.XX = 1–5
Indoor terminationSingle-coreNLS-8.7/15-1.XX = 1–5
Indoor terminationThree-coreNLS-8.7/15-3.XX = 1–5
Straight-through jointSingle-coreJLS-8.7/15-1.XX = 1–5
Straight-through jointThree-coreJLS-8.7/15-3.XX = 1–5

26/35 kV model families

Replace X using the matching voltage column above. Example: JLS-26/35-3.2 corresponds to the 120–185 mm² catalogue range.

FamilyCable coresModel patternSize indices
Outdoor terminationSingle-coreWLS-26/35-1.XX = 1–4
Outdoor terminationThree-coreWLS-26/35-3.XX = 1–4
Indoor terminationSingle-coreNLS-26/35-1.XX = 1–4
Indoor terminationThree-coreNLS-26/35-3.XX = 1–4
Straight-through jointSingle-coreJLS-26/35-1.XX = 1–4
Straight-through jointThree-coreJLS-26/35-3.XX = 1–4

Fit checks before ordering

The catalogue selection tables list conductor cross-section, but do not provide a usable diameter-over-insulation range for each model. Submit the actual cable data sheet for dimensional confirmation.

Confirm conductor material and construction, diameter over insulation, jacket diameter, screen and armour construction, equipment interface and environment. For joints, provide both cable ends. Do not infer insulation diameter from conductor cross-section.

26/35 kV catalogue technical data

These are catalogue values, not field commissioning instructions or an independent certification. Request the applicable model-specific test report and installation manual.

ItemCatalogue value / condition
Rated voltage / frequency26/35 kV, 50 Hz
Maximum operating voltage40.5 kV
Ambient temperature−40°C to +40°C
Rated conductor operating temperature90°C
Maximum conductor temperature at short circuit250°C; duration not stated in this table
AC withstand test117 kV, 5 min; no breakdown or flashover
Heating cycle test in air65 kV, conductor 95–100°C, 60 cycles
Heating cycle test in water65 kV, conductor 95–100°C, 30 cycles
Partial discharge at ambient temperature≤10 pC at 45 kV
Partial discharge at elevated temperature≤10 pC at 45 kV, 95–100°C

Wet withstand duration and certain impulse/power-frequency entries require confirmation from the model-specific test report. Test scope and acceptance criteria must match the supplied accessory and project requirements.

Reference: Zeeyi Electric Cold Shrink Terminal catalogue, printed pages 07 and 11–12. Model selection is subject to cable and application confirmation.

Engineering & Supply Support

From Model Selection to Export Delivery, Built for B2B Cable Projects

Beyond cold shrink cable accessory manufacturing, ZeeyiElec supports project-side selection logic, technical confirmation, and shipment documentation to reduce communication cycles and improve RFQ accuracy.

Model Matching Support

Assist with termination and joint model selection based on voltage class, cable core type, and conductor range.

Technical Data Alignment

Provide structured datasheet confirmation to align your project requirements with available cold shrink series.

OEM/ODM Collaboration

Support private labeling and specification-based supply workflows for utility contractors and industrial buyers.

Export Documentation

Commercial invoice, packing list, and shipment documents prepared for international procurement and customs clearance.

Application Scenarios

Where Cold Shrink Terminations and Joints Are Commonly Applied

Cold shrink cable accessories are widely used in medium-voltage distribution projects where installation consistency, insulation reliability, and maintenance accessibility are critical.

Utility Distribution Networks

10kV / 35kV

Used in power distribution feeder sections and branch connections for indoor/outdoor cable terminations and route continuity joints.

  • Substation outgoing cable interfaces
  • Feeder section extension and reconnection
  • Retrofit replacement in aged distribution lines

Typical products: outdoor termination kits, straight-through joint kits.

Industrial Power Systems

Indoor Priority

Suitable for factory substations and process plants that require stable medium-voltage cable insulation performance and organized maintenance workflow.

  • Motor control and distribution room cable ends
  • Production line expansion projects
  • Shutdown-window cable joint replacement

Typical products: indoor terminations + matched straight-through joints.

Commercial & Infrastructure Projects

Project Supply

Applied in integrated cable systems for buildings, transport support facilities, and public infrastructure requiring long service reliability.

  • Campus and complex MV distribution rooms
  • Tunnel/transport auxiliary power segments
  • Municipal upgrade and phased capacity expansion

Typical products: full-kit combinations by voltage class and core type.

Renewable Energy Collection Circuits

MV Collection

Used in medium-voltage collection lines and transition sections where project teams need repeatable installation and clear model control.

  • Cable transitions between equipment zones
  • Jointing segments during staged commissioning
  • Operation-period maintenance replacement

Typical products: outdoor/indoor terminations with compatible joint kits.

Contractor Maintenance Projects

Fast Turnaround

Preferred in service scenarios where teams need consistent field operations and reduced dependency on heat-based installation methods.

  • Emergency repair for damaged cable sections
  • Scheduled overhaul and cable rerouting work
  • Inventory-standardized maintenance packages

Typical products: standardized kits for common conductor ranges.

Export-Oriented EPC Procurement

Documentation-Ready

Fits EPC and international sourcing workflows that require structured model coding, clear technical confirmation, and shipment documentation support.

  • RFQ by voltage class + core type + quantity
  • Batch planning by indoor/outdoor/joint application
  • Commercial and logistics document alignment

Typical products: project bundles combining termination and joint families.

Selection reminder: For an accurate kit recommendation, provide the cable voltage rating, core count, conductor cross-section, insulation outside diameter, installation type (indoor termination, outdoor termination, or joint), and required quantity. Use the model tables to identify the product family, then confirm cable compatibility before ordering.
Project Planning

Selection Guide for Cold Shrink Systems

Identify the connection location first, then check the cable and equipment details against the selected kit documentation. A conductor size alone does not establish compatibility.

01

Voltage Check

Verify system rated voltage. Typical applications include 10kV (8.7/15kV) or 35kV (26/35kV) distribution networks.

02

Site Condition

Determine the environment: Indoor (compact switchgear) vs Outdoor (UV, humidity, and pollution protection).

03

Core Topology

Match the actual cable construction: single-core or three-core, insulation material, screen and armour. Confirm the required breakout and bonding components.

04

Sectional Area

Provide conductor material and cross-section together with diameter over insulation and overall cable diameter. Check each dimension against the exact kit range.

Selection Matrix

Operational ContextProduct FamilyPattern LogicClass
Outdoor Overhead/SubstationOutdoor TerminationWLS-XX/XX.X10kV – 35kV
Indoor equipment with a compatible termination interfaceIndoor TerminationNLS-XX/XX.X10kV – 35kV
Cable Extension / RepairStraight JointJLS-XX/XX.X10kV – 35kV
1-Core DistributionSingle-Core Kit…-1.XComponent
3-Core DistributionThree-Core Kit…-3.XCheck kit contents

Cable data to confirm before ordering

InputTermination kitJoint kit
Cable dimensionsConductor size, diameter over insulation and jacket diameterThe same dimensions for both cable ends
ConnectionEquipment terminal drawing, lug and available clearancesConductor connector and compatibility of both cable constructions
EnvironmentIndoor or outdoor exposure, pollution and altitudeBurial, water exposure, mechanical protection and installation space
DocumentsExact model data sheet, kit contents and installation instructionsExact model data sheet, bonding arrangement and installation instructions

Diameter over insulation is not the overall cable diameter. Request the model-specific application range before selecting a size suffix. For the functional differences, see cable termination vs cable joint.

Quality & Documentation

Quality Control and Export Documentation for Cold Shrink Cable Accessories

ZeeyiElec supports project-side verification with structured quality checks and practical documentation workflows for medium-voltage cold shrink cable termination and joint supply.

Production & Quality Control Focus

Typical control points used to improve consistency for cold shrink cable accessory supply.

Material Consistency

Silicone insulation body stability and appearance consistency verification across batch production.

Dimensional Check

Key size checkpoints aligned with model range and cable application mapping requirements.

Model Code Verification

Inner/outer label and carton marking consistency check against confirmed order model list.

Packing Integrity

Export packing confirmation for quantity, accessory completeness, and transport-readiness.

Step 1
Technical requirement review (voltage class / application / cable structure).
Step 2
Confirm the model and cable compatibility against the selected product datasheet and your project requirements.
Step 3
Production + quality checkpoint execution with delivery schedule coordination.
Step 4
Commercial and shipment document preparation for export dispatch.
FAQ & Resources

Cold Shrink Cable Termination FAQ & Technical References

Answers to common questions about cold shrink cable accessories, including installation method, service life, heat-shrink comparison, waterproof suitability, and cable termination type selection.

A cold shrink cable termination is a pre-expanded silicone insulation assembly that contracts onto the cable after removing the support core. It forms insulation and environmental sealing without flame or heating tools.
Cold shrink relies on elastic recovery and does not require a heat source; heat shrink needs controlled heating to recover. Cold shrink is often preferred where consistent field installation and reduced fire-risk operation are required.
Basic cable preparation tools are typically required, such as stripping and cleaning tools. For the shrink body itself, no torch or heat gun is needed; installers pull the removable core to complete recovery.
Service life depends on product quality, installation quality, load profile, and environment. In properly selected and installed MV systems, cold shrink accessories are designed for long-term operation comparable to project design expectations.
Cold shrink outdoor termination designs are commonly used in exposed environments. Final waterproof performance depends on correct model selection, cable preparation, and installation procedure compliance.
Yes, cold shrink joint systems are widely used in underground and buried distribution cable routes. Confirm voltage class, cable structure, and sealing system before final model selection.
The main families are cold shrink outdoor terminations, indoor terminations, and straight-through joints. Each family is further matched by voltage class, cable core type, and conductor cross-section range.
Common options include cold shrink terminations, heat shrink terminations, pre-molded separable interfaces, and resin/compound-based systems. Selection depends on project standards, environment, maintenance strategy, and installation conditions.
For engineering applications, professional controlled heating equipment is typically required for heat shrink systems. Household devices usually cannot provide stable temperature distribution for reliable electrical installation quality.
Provide the cable voltage rating, application type (indoor termination, outdoor termination, or joint), core count, conductor cross-section, insulation outside diameter, screen construction, and required quantity. Include your cable datasheet so the selected kit can be checked for compatibility before ordering.